Alber
offers a full line of battery test equipment, stationary battery monitors,
battery diagnostic systems, capacity test systems, resistance testers,
hydrometers and load banks.
Alber also offers battery
training seminars for battery maintenance and battery testing. Click a
photo below for a product brochure. Brochures and spec sheets for Alber
battery test equipment are also on the Tech Library page.
You may download a literature order form, complete it
on-screen, and send it to Alber as an email attachment.
|
|

|
|
Full Line Brochure
|
|

|
|
Full Line Brochure
|

|
Full Line Brochure
View a copy of the Alber full line
product brochure, which will help you select the Alber equipment best
suited to you needs.
|
|

|
|
Portable Test Equipment
|
|

|
|

<click
photo>
|

|
Cellcorder®
CRT-400 Cell Resistance Tester
New! CRT-400.
Call for Details!
The Cellcorder CRT-400 takes the same
reliable readings as the earlier CLC-200 and CRT-300 models. The Cellcorder
CRT-400 utilizes USB Flash drive technology, IR (infrared) communication,
and newly designed resistance and voltage test leads. It comes with a hard
shell carrying case, AC charger, and improved data trending and analysis
software. An optional printer is available.
|
|

|
|

<click
photo>
|
|
CVR+ Cell Voltage Recorder Plus
The
CVR+ cell voltage recorder by Alber directly measures and records cell
float voltage, uploads temperature and specific gravity (SG) measurement
data from a DMA‑35 or DMA‑35N digital hydrometer, and downloads
data to a computer running the Alber Battery Analysis Software (BAS).
|
|

|
|

|

|
DMA-35
Series Digital Storage Battery Hydrometers
These
compact, easy-to-use hydrometers measure density, specific gravity, and
concentration.
|
|

|
|

|

|
MLT-12
Momentary Battery Load Tester
This
portable battery tester provides pass/fail status for 12 volt modules. It
features 50 amp continuous load and complete rejection of AC ripple.
|
|

|
|

<click
photo>
|

|
PSC-10A
Programmable Smart Charger
This
charger provides 2 volt cells with up to 10 amps of charge current. Output
voltage is 2.85VDC maximum. The PSC-10A features polarity protection,
programmable equalization time, and programmable float charge time.
|
|

|
|
|
|

|
|
Continuous Battery Monitors
|
|

|
|

<click
photo>
|
|
BDS-40
Battery Monitoring and Diagnostic System
The
BDS-40, especially designed and optimized to monitor UPS batteries in
cabinets, continuously monitors all critical battery parameters, automatically
performs periodic resistance tests to verify the operating integrity of the
connected battery, and greatly improves the reliability of your DC power
system.
|
|

|
|
Product Description Guide
|
|
BDS-40
Monitor Product Description Guide
General
description of the BDS-40 configurations, system component specifications,
and communication option diagrams. See more guides below.
Book Rev 4.1. 25pp. 6 May 2011. File Size: 550K
|
|

|
|

<click
photo>
|

|
BDS-256XL
Battery Monitoring and Diagnostic System
The
BDS-256XL continuously monitors all critical battery parameters,
automatically performs periodic resistance tests to verify the operating
integrity of the connected battery, and greatly improves the reliability of
your DC power system. Site Survey Form
|
|

|
|
Product Description Guide
|
|
BDS-256XL Monitor
Product Description Guide
General
description of the new BDS-256XL configurations, system component
specifications, and communication option diagrams.
Book Rev 3.1. 31pp. 6 May 2011. File Size: 832K Site Survey Form
|
|

|
|

<click
photo>
|
|
BDSU-120
Battery Diagnostic System Universal
The BDSU-120 is a real time battery monitor
designed for utility bulk power systems and NERC compliance. The BDSU lets
you automate IEEE recommended practices for battery maintenance and testing
and will help you maintain complete and accurate maintenance records.
|
|

|
|

<click photo>
|

|
MPM-100
Battery Monitoring and Diagnostic System
The
MPM-100 multi-purpose monitor is a single module solution, containing data
collection, controller, and resistance test circuitry for all applications
of 140 volts or less.
|
|

|
|
Product Description Guide
|
|
MPM-100 Monitor
Product Description Guide
General
description of the MPM-100 configurations, system component specifications,
and communication option diagrams.
Book Rev 2.0. 18pp. 6 Mar 2007. File Size: 1.4M
|
|

|
|

<click
photo>
|
|
Universal
Xplorer Battery Monitor (UXTM)
The
Universal Xplorer Battery Monitor (UXTM) is a real time battery monitor
designed for use in telecommunications or in DC powered data centers.
|
|

|
|
|
|

|
|
Capacity Test Systems
|
|

|
|

<click
photo>
|

|
BCT-2000
Battery Capacity Test System
The
BCT-2000 tests any size string up to 256 cells, performs constant current
capacity and power capacity tests, supports UPS testing using AC load
banks, and supports run-down testing using system load.
|
|

|
|

|

|
Continuous
Load Unit
These DC
load units, which have automatic control and can interface with the
BCT-2000, may be used in both constant power or current applications.
|
|

|
|

|

|
SCT-600
/ SCT-1200 Single Cell Test and Charge System
The SCT
test system can discharge and charge one cell at a time. The test sequence
consists of discharging the cell to a selected end voltage at a programmed
load current, then charging to a selected charge voltage at a programmed
current limit for a time determined by the user.
|
|

|
|

|

|
RM-650
Recharge Module
The
RM-650 Recharge Module reconnects your discharged string back to the bus -
fast!
|
|

|
|
|
|

|
|
Seminars and Training
|
|

|
|
Seminars Page
Training Page
|
|
Alber Seminars
and Training
Alber
provides battery seminars and battery training for small or large groups at
your site or ours. Contact Alber for more details.
|