CLC-200

 

 

The Alber Cellcorder CLC-200 at a Glance

The Alber Cellcorder data storing, battery multimeter provides accurate information in a fraction of time. This lightweight unit displays and records readings of cell float voltage, internal cell resistance, and intercell connection resistance. You may enter other data, such as specific gravity and temperature, manually or automatically using a compatible hydrometer.

Use the Cellcorder on a single cell or multicell modules. Automatic data storage for seven strings of 256 cells each or 28 strings of 64 cells each saves time and ensures a permanent record of readings. An RS-232 port allows data transfer to a computer for further analysis and report generation.

The bright, four line by 20 character display shows test results and operation instructions. With its internal battery fully charged, the Cellcorder can test for six hours. Isolated operation makes the unit portable, safe, and easy to move around. Recharge or AC power is via a wall plug adapter.


System Features

Float Voltage Readings - The Cellcorder measures the voltage applied during full float operation. The voltage range covers all cells or modules up to 16 volts. Reading accuracy is to four full digits.

Internal Cell Resistance - The internal resistance of a cell is calculated by how that cell responds to a momentary load, using instantaneous voltage drop and applied load current. Algorithms make this measurement possible on cells floating on-line or off-line.

Intercell Resistance - The Cellcorder measures the resistance between two electrically connected cell terminals. The measurement consists of contact resistance and connector resistance at the points of connection to the cell terminals.


Auto Ranging - The Cellcorder automatically selects the correct voltage range, load resistor, and time for a test.

Data Extraction and Analysis - After testing, you may connect the Cellcorder via RS-232 to a computer to analyze test data, display results in bar graph or tab format, and print a test report or save it to a file. You can export this file in ASCII or comma-delimited format to have off-the-shelf programs or the optional Cellcorder trending software generate customized reports.


Cellcorder Advantages

Low Cost - Because the Alber Cellcorder replaces three instruments, each costing more than the Cellcorder, you will realize significant savings from taking more readings in less time and analyzing data more rapidly.

Multicell Capability -The Cellcorder provides readings on either single cells or multicell modules.

Reliable Readings - The Cellcorder performs superbly, even in high noise environments, without having to disconnect the battery from service. The instrument uses up to a 70 amp DC load (on 2V cells) to calculate internal cell resistance and intercell resistance. Circuitry rejects the 60Hz ripple often troublesome to AC-based impedance and conductance meters.


The CLC-200 Cellcorder comes with test leads, carrying case, download software, AC adapter, and interface cable. Data and trend analysis software is included.

 

Connection Options

 

| What's New | Home | About Us | Products | Services | Seminars | Sales Reps | Tech Library |

| Updates | Training | Contact | CRT-300 |

All content is the property of Albercorp.
Reproductions and/or copies of this web site, in whole or in part,
are strictly forbidden without prior written consent of Alber.
'Trust Your Batteries' and the Alber logo are trademarks of Albercorp.
Battcon is a registered trademark of Albercorp.
Alber
3103 No. Andrews Ave. Ext.
Pompano Beach, Florida 33064
(954) 623-6660

Copyright ©2012 Albércorp