TRUST YOUR BATTERIES™

 

 

Technology and Solutions for Battery Testing

 

BCT-2000
Battery Capacity Test System

 

 

BCT-2000
P/N 1000-012 (BCT 128) 1000-015 (BCT 256)


The best proven method for determining whether a battery will perform is to test it under load conditions. Proper load testing is the only way to determine where the battery resides on its expected life curve. The Albér BCT-2000 capacity test system will test any battery in service today.

Load testing is essential for any storage battery system that protects equipment or a critical service. Because the battery is almost always the least reliable component, load testing with the BCT-2000 should be done on a regular basis to ensure reliability. The BCT performs battery load tests using load banks or, in some cases, the actual system load.

Capacity Test

The BCT-2000 performs a capacity test using a programmed, constant current or constant power load. This test predicts reliability and remaining battery life before replacement is necessary.

Integrity Test

An integrity test, using a high current momentary load, lets you identify weak cells and conduction paths.

Data Acquisition Module and Data Logging Unit

The BCT is a combination load control and data logging system consisting of a data acquisition module and a laptop computer data logging unit. The data acquisition module acquires all cell voltage, overall string voltage, and current readings and is available in 128 cell and 256 cell versions. The computer data logging unit displays the programming parameters for the test.

The BCT's proprietary interface circuits and custom software control all standard Albér continuous and momentary load units. The standard BCT-2000 can be programmed to apply a constant current or constant power load on any battery string up to 600VDC. During a load test, the system records overall voltage, load current, and up to 256 cell voltages. Programmable alarm levels warn of low voltages and can automatically pause testing before any cell reaches reversal or an unsafe state.

 

 

Product Brochure

Battery Capacity Testing Explained

 

| What's New | Home | About Us | Products | Services | Seminars | Sales Reps | Tech Library |

| Updates | Training | Contact |

All content is the property of Albercorp.
Reproductions and/or copies of this web site, in whole or in part,
are strictly forbidden without prior written consent of Alber.
'Trust Your Batteries' and the Alber logo are trademarks of Albercorp.
Battcon is a registered trademark of Albercorp.
Alber
3103 No. Andrews Ave. Ext.
Pompano Beach, Florida 33064
(954) 623-6660

Copyright ©2012 Albércorp